Operating speed |
0.01mm to 50m/sec (at pin plunger) |
Operating frequency |
Mechanically : 120 operations/min.
Electrically : 30 operations/min. |
Contact resistance |
15M Ω max. (initial) |
Insulation resistance |
100M Ω min. (at 500 VDC) |
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
2,000 VAC, 50/60 Hz for 1 minute between current-carrying and non-current carrying part and between each terminals and ground |
Vibration |
Malfunction durability : 10 to 55Hz; 1.5mm double amplitude |
Shock |
Mechanical durability : Approx. 1,000m/sec2 (approx. 100G’s)
Malfunction durability : Approx. 300m/sec2 (approx. 30G’s) |
Ambient temperature |
Operating: -10oC to +80oC |
Humidity |
95%RH max, (at +20oC to +35oC) |
Service life |
Mechanically : 10,000,000 operations min.(at rate OT value)
Electrically : 500,000 operations min. |
Degree of protection |
IEC : IP65 |